Severe Duty Gas Flow Controller - Model 3600

3600 The Parker 3600 Series Digital Mass Flow Instruments are designed specifically for applications in severe industrial environments. Various models in this series meet IP 66, NEMA 4X and Class I, Div. 2. Series 3600 devices will satisfy food & beverage, biotech/pharmaceutical and chemical processing applications that require frequent wash down, as well as chemical/petrochemical and industrial process applications where hazardous location certification is required.

Product Highlights:
  • NEMA 4X, IP 66 Watertight Construction
  • Listed for Class 1, Division 2 Environments
  • Industry Standard TURCKā„¢ Electrical Connectors
  • Stainless Steel Body and Internal Components
  • Digital Electronics
  • Multi-Gas Capability
  • 4-20 mA, Modbus, Profibus or DeviceNet I/O
  • Self-Diagnostics


Request additional info or a quote.
Get Info or a Quote

3600 Series: Severe Duty Mass Flow Meter & Controller

High Performance Gas Flow Control for Industrial Environments
The Parker 3600 Series Digital Mass Flow Instruments are designed specifically for applications in severe industrial environments. Various models in this series meet IP 66, NEMA 4X and Class I, Div. 2. Series 3600 devices will satisfy food & beverage, biotech/pharmaceutical and chemical processing applications that require frequent wash down, as well as chemical/petrochemical and industrial process applications where hazardous location certification is required.

Digital control electronics provide unparalleled accuracy, repeatability and control stability. TURCK™ electrical connectors simplify wiring and replacement. Percentage of reading accuracy, fast response and multi-gas capability, along with analog or digital I/O options make the Parker 3600 Series a versatile solution to many demanding applications.

Product Features
• NEMA 4X, IP 66 Watertight Construction
• Listed for Class 1, Division 2 Environments
• Industry Standard TURCK™ Electrical Connectors
• Stainless Steel Body and Internal Components
• Digital Electronics
• Multi-Gas Capability
• 4-20 mA, Modbus, Profibus or DeviceNet I/O
• Self-Diagnostics

SPECIFICATIONS
Flow Capacity
Model 3601 controller & 3611 meter:
100 SCCM to 10 SLPM
Model 3602 controller and 3612 meter:
10 SLPM to 100 SLPM (nitrogen equivalent)
Response Time (per SEMI E17-91 Settling Time)
1 to 2 seconds (consult factory for applications requiring faster response times)
Accuracy and Linearity
±1.0% of reading (20%-100% full scale) & ±0.8% of reading plus ±0.2% full scale (below 20% full scale)
Repeatability
Within ±0.2% of rate at any constant temperature within operating temperature range
Rangeability (Control Range)
50:1 (2%-100% full scale) (accuracy and control)
Ambient Temperature Range
Devicenet: -10°C to 60°C (14°F to 140°F)
All Other Protocols: -10°C to 70°C (14°F to 158°F)
Temperature Coefficient (per SEMI E18-91 Zero Effect and Span Effect)
±0.05% full scale/ºC of zero
±0.05% of reading/°C of span
Maximum Operating Pressure:
1500 PSIG
Pressure Coefficient (per SEMI E28-92 Total Calibration Effect)
± 0.1%/atmosphere typical using nitrogen (N2)
Warm-up Time:
10 minutes
Setpoint Input/Flow Signal Output
Setpoint                     Flow Signal
0-5 Vdc         0-5 Vdc (2K ohm min. load resist.)
0-10 Vdc       0-10 Vdc (3K ohm min. load resist.)
4-20 mAdc    4-20 mAdc (sourcing) (refer to load resistance values below)
0-100%        0-100%
(Modbus, Profibus, DeviceNet)
Load resistance values for 4-20 mAdc flow signal output: 200-750 ohm for 15-30 Vdc loop supply voltage
Power Supply Requirements
All models operate from nominal power supply voltages of +15 to +24 Vdc. Current Consumption <250 mAdc (MFC), <70 mAdc (MFM)
Electrical Connections
For Class1, Div 2, NEMA4X, IP66
External Electrical Connectors on Device
Analog: TURCK™ minifast
Digital: TURCK™ minifast


Mating Cordsets (TURCK™, Inc.):

Analog: TURCK™ p/n P-RKV 71-219-*M
Digital: TURCK™ p/n P-RKV 55-099-*M (Modbus)
Digital: TURCK™ p/n RSCV RKCV 5711-*M
(Devicenet; male/female)
Digital: TURCK™ p/n RKCV 5711-*M
(Devicenet; female/flying leads)
Digital: for Profibus, contact factory
* Indicates cordset length
Mating Cordset for Internal Electrical Connector inside Device:
RS232 Comm: TURCK™ p/n PKG 3Z-*
* Indicates cordset length
For NEMA4X, IP66 Device
External Electrical Connectors on Device
Analog: TURCK™ eurofast
Digital: TURCK™ eurofast
Mating Cordsets (Turck, Inc.):
Analog: TURCK™ p/n RKSV 8T-*
Digital: TURCK™ p/n RKSV 4.5T-* (Modbus)
Digital: TURCK™ p/n RKCV 5711-*M
(Devicenet; female/flying leads)
TURCK™ p/n RSCV RKCV 5711-*M
(Devicenet; female/male)
Digital: TURCK™ p/n RKSWV 455-*M
(Profibus; female/flying leads)
TURCK™ p/n RSSWV RKSWV 455-*M
(Profibus; female/male)
* Cordset length indicator

MATERIALS OF CONSTRUCTION
Body
316 Stainless Steel
Sensor Assembly
316L Stainless Steel
Orifice
316 Stainless Steel (MFCs only)
Valve Components (Wetted)
302 Stainless Steel, 316 Stainless Steel, 430F Stainless Steel and Sandvik® (MFCs only)
Elastomers
Buna N, EPDM, Kalrez®, Neoprene or Viton®
Process Connections
316 Stainless Steel
Sandvik® is a registered trademark of AB Sandvik Materials Technology.
Kalrez® and Viton® are registered trademarks of DuPont Dow Elastomers L.L.C.

Download the complete PDF for more details and ordering information

Request info or a quote on this product

Request Information

Get prompt assistance on a Parker flow product or application challenge.

Get A Quote

Need pricing on a specific or custom Parker Instrument?

Locate A Representative

Use our Rep Locator to find the appropriate representative for your area.
We'd love to share this file with you, but first you need to log in or register for an account.

Email:
 
First Name:
Last Name:
Email:
Phone:
Company:
Title:
 
Porter Instrument Division respects your privacy, and does not share information with third party companies. View website policies and contact information.